{"product_id":"1500w-2000w-mppt-inverter-charger-dc24v-to-ac220v-pure-sine-wave-solar-utility","title":"Epever UPower MPPT Inverter\/Charger DC24V to AC220V\/230V Pure Sine Wave 1500W\/2000W (UP1500\/UP2000)","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\u003cp\u003eThe Epever UPower series MPPT inverter\/charger combines solar \u0026amp; utility charging with pure sine wave AC output for DC 24V battery systems, providing AC 220V\/230V output with 50Hz\/60Hz auto frequency. It supports multiple charging priorities and output modes to suit different off-grid and backup power setups.\u003c\/p\u003e\u003ch2\u003eModels\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUP1500-M3222\u003c\/strong\u003e: Output power (15 min) 1500W; Max. PV open circuit voltage 100V \/ 92V; Max. PV charging current 30A; Max. PV input power 780W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUP2000-M3322\u003c\/strong\u003e: Output power (15 min) 2000W; Max. PV open circuit voltage 100V \/ 92V; Max. PV charging current 30A; Max. PV input power 780W.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePure sine wave output (SPWM technology)\u003c\/li\u003e\n\u003cli\u003eFully digitalized voltage and current double closed-loop control\u003c\/li\u003e\n\u003cli\u003eMPPT tracking efficiency: ≥99.5%\u003c\/li\u003e\n\u003cli\u003eFour charging modes: Solar priority; Utility priority; Utility \u0026amp; Solar; Solar\u003c\/li\u003e\n\u003cli\u003eTwo output modes: Battery; Utility\u003c\/li\u003e\n\u003cli\u003eLCD for dynamic display of running data and operating state\u003c\/li\u003e\n\u003cli\u003eCommon interface and advanced interface\u003c\/li\u003e\n\u003cli\u003eMultiple LED indicators for operating status\u003c\/li\u003e\n\u003cli\u003e2P circuit breaker at the utility input end\u003c\/li\u003e\n\u003cli\u003eIndependent control of AC output via AC OUT button\u003c\/li\u003e\n\u003cli\u003eBattery temperature compensation function\u003c\/li\u003e\n\u003cli\u003eExtensive electronic protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFor system compatibility checks (PV string voltage, battery bank, and AC loads), contact \u003ca href=\"mailto:service@tsolar.top\"\u003eservice@tsolar.top\u003c\/a\u003e or visit https:\/\/tsolar.top\/.\u003c\/p\u003e\u003ch2\u003eProtection Functions\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePV over current protection\u003c\/li\u003e\n\u003cli\u003ePV short circuit protection\u003c\/li\u003e\n\u003cli\u003ePV reverse polarity protection\u003c\/li\u003e\n\u003cli\u003eNight reverse charging protection\u003c\/li\u003e\n\u003cli\u003eUtility input overvoltage protection\u003c\/li\u003e\n\u003cli\u003eUtility input under voltage protection\u003c\/li\u003e\n\u003cli\u003eBattery overvoltage protection\u003c\/li\u003e\n\u003cli\u003eBattery over discharge protection\u003c\/li\u003e\n\u003cli\u003eLoad short circuit protection\u003c\/li\u003e\n\u003cli\u003eLoad overload protection\u003c\/li\u003e\n\u003cli\u003eDevice overheating protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications (Extracted)\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eUP1500-M3222\u003c\/th\u003e\n\u003cth\u003eUP2000-M3322\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem battery voltage\u003c\/td\u003e\n\u003ctd\u003e24VDC\u003c\/td\u003e\n\u003ctd\u003e24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery input voltage range\u003c\/td\u003e\n\u003ctd\u003e21.6~32VDC\u003c\/td\u003e\n\u003ctd\u003e21.6~32VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous output power\u003c\/td\u003e\n\u003ctd\u003e1200W\u003c\/td\u003e\n\u003ctd\u003e1600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power (15 min)\u003c\/td\u003e\n\u003ctd\u003e1500W\u003c\/td\u003e\n\u003ctd\u003e2000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload power (5 s)\u003c\/td\u003e\n\u003ctd\u003e2400W\u003c\/td\u003e\n\u003ctd\u003e3200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. surge power\u003c\/td\u003e\n\u003ctd\u003e3000W\u003c\/td\u003e\n\u003ctd\u003e4000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e220VAC ±3%, 230VAC (-7%~+3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput wave\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePure Sine Wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDistortion THD\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;3% (12V or 24V resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20mS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtility input voltage range (working)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e160VAC~280VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtility starting voltage range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e170VAC~270VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. utility charge current\u003c\/td\u003e\n\u003ctd\u003e20A\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV open circuit voltage\u003c\/td\u003e\n\u003ctd\u003e100V \/ 92V\u003c\/td\u003e\n\u003ctd\u003e100V \/ 92V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV input power\u003c\/td\u003e\n\u003ctd\u003e780W\u003c\/td\u003e\n\u003ctd\u003e780W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV charging current\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEqualization voltage\u003c\/td\u003e\n\u003ctd\u003e29.2V\u003c\/td\u003e\n\u003ctd\u003e29.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoost voltage\u003c\/td\u003e\n\u003ctd\u003e28.8V\u003c\/td\u003e\n\u003ctd\u003e28.8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloat voltage\u003c\/td\u003e\n\u003ctd\u003e27.6V\u003c\/td\u003e\n\u003ctd\u003e27.6V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTracking efficiency\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≥99.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging conversion efficiency\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e≤98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature compensate coefficient (default)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-3mV\/°C\/2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load consumption\u003c\/td\u003e\n\u003ctd\u003e≤0.6A\u003c\/td\u003e\n\u003ctd\u003e≤0.8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt;95% (N.C.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking environment temperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-20°C~50°C (100% input and output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e444×300×126mm\u003c\/td\u003e\n\u003ctd\u003e444×300×126mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting dimension\u003c\/td\u003e\n\u003ctd\u003e230mm\u003c\/td\u003e\n\u003ctd\u003e230mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting hole size\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eΦ8mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.4kg\u003c\/td\u003e\n\u003ctd\u003e8.5kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eVideo Demo\u003c\/h2\u003e\u003ciframe height=\"190\" src=\"https:\/\/www.youtube.com\/embed\/JkviR5FC37w\" title=\"What is an Inverter\/Charger and how it works? EPEVER UPOWER series introduced\" width=\"300\"\u003e\u003c\/iframe\u003e\u003ch2 id=\"details\"\u003eDetails\u003c\/h2\u003e\u003cdiv class=\"details-gallery\"\u003e\n\u003cimg alt=\"Epever 1500W 2000W MPPT Inverter\/Charger DC24V to AC220V Pure Sine Wave Solar \u0026amp; Utility\" loading=\"lazy\" src=\"https:\/\/tsolar.top\/cdn\/shop\/files\/Epever-1500W-2000W-MPPT-InverterCharger-DC24V-to-AC220V.png?v=1776820916\"\u003e\u003cp\u003eEpever UPower MPPT inverter models cover 12V and 24V battery systems with pure sine wave output and multiple power options.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"EPEVER","offers":[{"title":"1500W","offer_id":52208683745554,"sku":"11140-1","price":520.99,"currency_code":"USD","in_stock":true},{"title":"2000W","offer_id":52208683778322,"sku":"11140-2","price":549.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/2860\/6994\/files\/c1c82c0584cc8b92bd46c82f5476553_7e71ae30-c564-4077-94a8-e4331ba58dc8.png?v=1776761448","url":"https:\/\/tsolar.top\/products\/1500w-2000w-mppt-inverter-charger-dc24v-to-ac220v-pure-sine-wave-solar-utility","provider":"TSolar","version":"1.0","type":"link"}