{"product_id":"powmr-24v-3200w-110v-hybrid-solar-inverter-mppt-60a-charger-controller-max-pv-solar-108vdc-inversores-hibridos-solares-for-home","title":"PowMr POW-LVM3.2K-24V 3200W 24V Hybrid Solar Inverter Charger 110\/120Vac, 60A MPPT, 108Vdc PV","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\u003cp\u003eThe PowMr POW-LVM3.2K-24V is a 24V hybrid solar inverter charger with pure sine wave AC output and a built-in MPPT solar charge controller. It integrates solar charging, mains (utility) charging, and inverter output, with selectable charging and output priority modes for home and off-grid power systems.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePure sine wave inverter output\u003c\/li\u003e\n\u003cli\u003eBuilt-in MPPT solar charge controller: 0–60A (settable); MPPT voltage range 30–90Vdc\u003c\/li\u003e\n\u003cli\u003eAC charger: 0–40A (settable); hybrid charging (AC + PV): 0–100A (settable)\u003c\/li\u003e\n\u003cli\u003eCharging modes: Only Solar, Utility Priority, Solar Priority, Solar + Utility\u003c\/li\u003e\n\u003cli\u003eOutput modes: Solar priority, Utility priority, SBU mode\u003c\/li\u003e\n\u003cli\u003eSupports lead-acid or lithium battery; lithium battery activation via PV or mains power\u003c\/li\u003e\n\u003cli\u003eLCD\/LED status display; supports real-time monitoring via SmartESS app (WiFi\/GPRS data acquisition module noted as purchased separately)\u003c\/li\u003e\n\u003cli\u003eProtections listed: short circuit, over-load, over current, backfill protection, over voltage, under voltage, over-temperature, over charge\u003c\/li\u003e\n\u003cli\u003eForced air cooling with variable-speed fan; energy-saving mode (load ≤ 50W)\u003c\/li\u003e\n\u003cli\u003eCommunication interface: USB \/ CAN \/ RS485 (WiFi\/GPRS) \/ Dry contact\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFor configuration support (battery settings, charging priority, monitoring options), contact service@tsolar.top.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003ePowMr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePOW-LVM3.2K-24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eHybrid solar inverter charger (pure sine wave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIs Smart Device\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput type\u003c\/td\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e45 x 36.5 x 18.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.3KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMainland China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-concerned chemical\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustomized\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAC Mode (Input \/ Bypass)\u003c\/h3\u003e\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input voltage\u003c\/td\u003e\n\u003ctd\u003e110\/120Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage range\u003c\/td\u003e\n\u003ctd\u003e(90Vac~140Vac) ±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz (Auto detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload\/short-circuit protection\u003c\/td\u003e\n\u003ctd\u003eCircuit breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. efficiency (AC mode)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum bypass overload current\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC input voltage (wiring diagram label)\u003c\/td\u003e\n\u003ctd\u003e120Vac±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC bypass current (wiring diagram label)\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC charge current (wiring diagram label)\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC wire (wiring diagram label)\u003c\/td\u003e\n\u003ctd\u003e10AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eInverter Mode (Output)\u003c\/h3\u003e\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output power (VA)\u003c\/td\u003e\n\u003ctd\u003e3200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output power (W)\u003c\/td\u003e\n\u003ctd\u003e3200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output voltage\u003c\/td\u003e\n\u003ctd\u003e120Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. efficiency (as labeled)\u003c\/td\u003e\n\u003ctd\u003e6000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated battery input voltage\u003c\/td\u003e\n\u003ctd\u003e24V (Minimum starting voltage 22V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower saving mode\u003c\/td\u003e\n\u003ctd\u003eLoad ≤ 50W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC output power (wiring diagram label)\u003c\/td\u003e\n\u003ctd\u003e≤ 3200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage (wiring diagram label)\u003c\/td\u003e\n\u003ctd\u003e120Vac±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (wiring diagram label)\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eAC Charging\u003c\/h3\u003e\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery type\u003c\/td\u003e\n\u003ctd\u003eLead acid or lithium battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. charging current (settable)\u003c\/td\u003e\n\u003ctd\u003e0–40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharge voltage range\u003c\/td\u003e\n\u003ctd\u003e20–33Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvercharge protection\u003c\/td\u003e\n\u003ctd\u003eAlarm and stop charging after 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003ePV Charging (MPPT)\u003c\/h3\u003e\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV open-circuit voltage\u003c\/td\u003e\n\u003ctd\u003e108Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV operating voltage range\u003c\/td\u003e\n\u003ctd\u003e30–108Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT voltage range\u003c\/td\u003e\n\u003ctd\u003e30–90Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery voltage range\u003c\/td\u003e\n\u003ctd\u003e20–33Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum PV input power\u003c\/td\u003e\n\u003ctd\u003e1600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV charging current range (settable)\u003c\/td\u003e\n\u003ctd\u003e0–60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV start-up\/starting voltage (labels)\u003c\/td\u003e\n\u003ctd\u003e30V (start-up voltage must be greater than 30V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax PV input current (wiring diagram label)\u003c\/td\u003e\n\u003ctd\u003e≤ 60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV wire (wiring diagram label)\u003c\/td\u003e\n\u003ctd\u003e12–10AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eHybrid Charging (AC + PV)\u003c\/h3\u003e\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eMax. hybrid charging current (settable)\u003c\/td\u003e\n\u003ctd\u003e0–100A\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eEnvironmental \u0026amp; Compliance\u003c\/h3\u003e\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCE (IEC 62109-1) \/ CETL (UL 1741 \/ CSA C22.2 NO.107.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC certification level\u003c\/td\u003e\n\u003ctd\u003eEN61000, C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature range\u003c\/td\u003e\n\u003ctd\u003e-10°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature range\u003c\/td\u003e\n\u003ctd\u003e-25°C ~ 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003eForced air cooling, variable speed of fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication interface\u003c\/td\u003e\n\u003ctd\u003eUSB \/ CAN \/ RS485 (WiFi\/GPRS) \/ Dry contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eBattery Notes (wiring diagram labels)\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBattery type: 24V lithium \/ lead acid\u003c\/li\u003e\n\u003cli\u003eRecommended battery capacity: 200AH\u003c\/li\u003e\n\u003cli\u003eBattery wire: 2AWG\u003c\/li\u003e\n\u003cli\u003eMax charge current: 100A\u003c\/li\u003e\n\u003cli\u003eThe battery must be connected\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOff-grid and hybrid home solar power systems (24V battery systems, 110\/120Vac output)\u003c\/li\u003e\n\u003cli\u003eSolar + utility (mains) + generator battery charging (generator support is stated)\u003c\/li\u003e\n\u003cli\u003eBackup power setups requiring selectable charging\/output priority\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"details\"\u003eDetails\u003c\/h2\u003e\u003cdiv class=\"details-gallery\"\u003e\n\u003cimg alt=\"PowMr POW-LVM3.2K-24V 3200W 24V hybrid solar inverter charger with 60A MPPT, 110\/120Vac output\" loading=\"lazy\" src=\"https:\/\/tsolar.top\/cdn\/shop\/files\/PowMr-24V-3200W-110V-Hybrid-Solar-Inverter-MPPT-60A-Charger.jpg?v=1779106106\"\u003e\u003cp\u003ePure sine wave 3200W output with built-in MPPT charging and utility AC charging for 24V battery systems.\u003c\/p\u003e\n\u003cimg alt=\"LCD HD display screen views for PowMr hybrid inverter, showing real-time PV system operating data readouts\" loading=\"lazy\" src=\"https:\/\/tsolar.top\/cdn\/shop\/files\/PowMr-24V-3200W-110V-Hybrid-Solar-Inverter-MPPT-60A-Charger_ed773c46-e706-493b-b606-af0246a28a9b.jpg?v=1779106115\"\u003e\u003cp\u003eThe front LCD screen provides at-a-glance system status and operating data during charging and inverter use.\u003c\/p\u003e\n\u003cimg alt=\"Wall-mounted PowMr inverter in home interior setting, compatible with AGM, GEL, flooded, lithium and sealed batteries\" loading=\"lazy\" src=\"https:\/\/tsolar.top\/cdn\/shop\/files\/PowMr-24V-3200W-110V-Hybrid-Solar-Inverter-MPPT-60A-Charger_2dee1d22-fcb2-4869-ac7f-e0c0a1e63a95.jpg?v=1779106124\"\u003e\u003cp\u003eDesigned for home and off-grid setups and supports common lead-acid types plus lithium batteries.\u003c\/p\u003e\n\u003cimg alt=\"Charging and output priority modes graphic for PowMr hybrid solar inverter: solar, utility, solar+utility and SBU options\" loading=\"lazy\" src=\"https:\/\/tsolar.top\/cdn\/shop\/files\/PowMr-24V-3200W-110V-Hybrid-Solar-Inverter-MPPT-60A-Charger_c44098df-368d-4151-b9ac-49dd79552ee7.jpg?v=1779106134\"\u003e\u003cp\u003eSelectable charging and output priority modes help balance solar, utility power, and battery use.\u003c\/p\u003e\n\u003cimg alt=\"SmartESS app monitoring for PowMr inverter, with iOS and Android download badges and optional WiFi\/GPRS module\" loading=\"lazy\" src=\"https:\/\/tsolar.top\/cdn\/shop\/files\/PowMr-24V-3200W-110V-Hybrid-Solar-Inverter-MPPT-60A-Charger_e79aad0e-2676-4203-8cdf-a921fd7d23d6.jpg?v=1779106143\"\u003e\u003cp\u003eOptional SmartESS app monitoring is available with a WiFi\/GPRS data acquisition module (sold separately).\u003c\/p\u003e\n\u003cimg alt=\"Protection features graphic for PowMr inverter: short circuit, overload, overcurrent, backfill, over\/under voltage, over-temp\" loading=\"lazy\" src=\"https:\/\/tsolar.top\/cdn\/shop\/files\/PowMr-24V-3200W-110V-Hybrid-Solar-Inverter-MPPT-60A-Charger_1ee301e6-3b9b-4ce0-ad97-cd43d66fcdbb.jpg?v=1779106152\"\u003e\u003cp\u003eBuilt-in protection features support safer operation across common fault and temperature conditions.\u003c\/p\u003e\n\u003cimg alt=\"Feature panels highlighting temperature-controlled cooling, multiple protections, and LCD\/LED indicators on PowMr inverter\" loading=\"lazy\" src=\"https:\/\/tsolar.top\/cdn\/shop\/files\/PowMr-24V-3200W-110V-Hybrid-Solar-Inverter-MPPT-60A-Charger_98fc3147-8821-48c9-b408-8b2f11beb2ef.jpg?v=1779106162\"\u003e\u003cp\u003eVariable-speed fan cooling and clear LCD\/LED indicators support everyday monitoring and reliable performance.\u003c\/p\u003e\n\u003cimg alt=\"Wiring diagram and technical specifications for PowMr POW-LVM3.2K-24V, including PV input, AC input\/output, and battery connections\" loading=\"lazy\" src=\"https:\/\/tsolar.top\/cdn\/shop\/files\/PowMr-24V-3200W-110V-Hybrid-Solar-Inverter-MPPT-60A-Charger_1f2ed3ca-d175-46b4-9003-02014d431e15.jpg?v=1779106171\"\u003e\u003cp\u003eReference wiring overview for PV input, AC input\/output, and 24V battery connections during installation.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"PowMr","offers":[{"title":"3.2KW with WIFI \/ 110-120V \/ United States|24V","offer_id":52239858499858,"sku":"1005011659520230-3.2KW with WIFI-110-120V-United States-24V","price":411.59,"currency_code":"USD","in_stock":true},{"title":"3.2KW without WIFI \/ 110-120V \/ United States|24V","offer_id":52239858532626,"sku":"1005011659520230-3.2KW without WIFI-110-120V-United States-24V","price":366.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/2860\/6994\/files\/S02e8de199454446f84e6fba537140474y.webp?v=1777887281","url":"https:\/\/tsolar.top\/products\/powmr-24v-3200w-110v-hybrid-solar-inverter-mppt-60a-charger-controller-max-pv-solar-108vdc-inversores-hibridos-solares-for-home","provider":"TSolar","version":"1.0","type":"link"}