{"product_id":"powmr-4-2kw-6-2kw-hybrid-solar-inverter-24v-48v-to-220vac-mppt-120a-charge-controller-450v-max-pv-voltage-for-home-solar-system","title":"PowMr POW-HVM4.2K-24V-E \/ POW-HVM6.2K-48V-E Hybrid Solar Inverter 220Vac MPPT 120A 450V","description":"\u003ch2\u003eOverview\u003c\/h2\u003e\u003cp\u003eThe PowMr hybrid solar inverter (models POW-HVM4.2K-24V-E and POW-HVM6.2K-48V-E) combines a pure sine wave inverter, MPPT solar charge controller, and AC charger for home solar systems. It supports dual output (two-load output power) and provides configurable charging\/output modes via LCD settings.\u003c\/p\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePure sine wave output (utility or generator input supported)\u003c\/li\u003e\n\u003cli\u003eBuilt-in MPPT solar charge controller: 120A max charging current (AC charger plus solar charger)\u003c\/li\u003e\n\u003cli\u003ePV MPPT tracking range: 60Vdc~450Vdc; max PV array open circuit voltage: 500Vdc\u003c\/li\u003e\n\u003cli\u003e3 charging modes: Only Solar, Solar First, Solar \u0026amp; Utility\u003c\/li\u003e\n\u003cli\u003e3 output modes: SUB, SBU, MKS\u003c\/li\u003e\n\u003cli\u003eBattery type selections shown: AGM, GEL, FLD, LI, SLD, USER\u003c\/li\u003e\n\u003cli\u003eAuto-restart during AC power recovery\u003c\/li\u003e\n\u003cli\u003eProtection functions shown: overload, overvoltage, undervoltage, overtemperature, short circuit, battery reverse polarity\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFor wiring and configuration assistance, contact \u003ca href=\"https:\/\/tsolar.top\/\"\u003ehttps:\/\/tsolar.top\/\u003c\/a\u003e or email \u003ca href=\"mailto:service@tsolar.top\"\u003eservice@tsolar.top\u003c\/a\u003e.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ch3\u003eGeneral\u003c\/h3\u003e\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003ePowMr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003ePOW-HVM4.2K-24V-E \/ POW-HVM6.2K-48V-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIs Smart Device\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-concerned chemical\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMainland China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDUAL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eMPPT 120A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50Hz\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e45*36*15cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eis_customized\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eModel Comparison\u003c\/h3\u003e\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Model\u003c\/td\u003e\n\u003ctd\u003ePOW-HVM4.2K-24V-E\u003c\/td\u003e\n\u003ctd\u003ePOW-HVM6.2K-48V-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eLine Mode Specifications\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Waveform\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePure Sine Wave(Utility or Generator)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e230Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax AC Input Voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e300Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency(Line Mode)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026gt;95%( Rated R load,battery full charged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e10ms typical(UPS);20ms typical(Appliances)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eInverter Mode Specifications\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power\u003c\/td\u003e\n\u003ctd\u003e4.2KW\u003c\/td\u003e\n\u003ctd\u003e6.2KW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Waveform\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePure Sine Wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Regulation\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e230Vac±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e50HZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Efficiency\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3s@≥150% load;5s@101%~150% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Capacity\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2* rated power for 5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal DC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24Vdc\u003c\/td\u003e\n\u003ctd\u003e48Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold Start Voltage\u003c\/td\u003e\n\u003ctd\u003e23.0Vdc\u003c\/td\u003e\n\u003ctd\u003e46.0Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo Load Power Consumption\u003c\/td\u003e\n\u003ctd\u003e25W\u003c\/td\u003e\n\u003ctd\u003e50W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eCharge Mode Specifications\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging Algorithm\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3-Step\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Charging Current (Max)\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV Array Power\u003c\/td\u003e\n\u003ctd\u003e6200W\u003c\/td\u003e\n\u003ctd\u003e8000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal PV Voltage\u003c\/td\u003e\n\u003ctd\u003e240Vdc\u003c\/td\u003e\n\u003ctd\u003e360Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV Array MPPT Voltage Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e60Vdc~450Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. PV Array Open Circuit Voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e500Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Charging Current(AC charger plus solar charger)\u003c\/td\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eGrid-Tie Operation\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e220\/230\/240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeed-in Grid Voltage Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e195-253VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeed-in Grid Frequency Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e49-51±1Hz\/59-61±1Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Current\u003c\/td\u003e\n\u003ctd\u003e18.2A\u003c\/td\u003e\n\u003ctd\u003e26.9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Conversion Efficiency(DC\/AC)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e\u003cstrong\u003eTwo Load Output Power\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Load\u003c\/td\u003e\n\u003ctd\u003e4200W\u003c\/td\u003e\n\u003ctd\u003e6200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Main Load\u003c\/td\u003e\n\u003ctd\u003e4200W\u003c\/td\u003e\n\u003ctd\u003e6200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Second Load Range\u003c\/td\u003e\n\u003ctd\u003e840W~2940W\u003c\/td\u003e\n\u003ctd\u003e1240W~4340W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Load Cut Off Voltage\u003c\/td\u003e\n\u003ctd\u003e26VDC\u003c\/td\u003e\n\u003ctd\u003e52VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Load Return Voltage\u003c\/td\u003e\n\u003ctd\u003e27VDC\u003c\/td\u003e\n\u003ctd\u003e54VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eHome solar system inverter\/charger setups\u003c\/li\u003e\n\u003cli\u003eSystems using solar panels with utility grid and\/or generator input\u003c\/li\u003e\n\u003cli\u003eDual-load output scenarios where a main load and a second load range are required\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"details\"\u003eDetails\u003c\/h2\u003e\u003cdiv class=\"details-gallery\"\u003e\n\u003cimg alt=\"PowMr POW-HVM hybrid solar inverter charging modes for home solar—Solar First, Solar \u0026amp; Utility, Only Solar\" loading=\"lazy\" src=\"https:\/\/tsolar.top\/cdn\/shop\/files\/PowMr-42KW-62KW-Hybrid-Solar-Inverter-24V-48V-to-220Vac.jpg?v=1779106593\"\u003e\u003cp\u003eChoose the charging priority that fits your setup—Solar First, Solar \u0026amp; Utility, or Only Solar—to make the most of available PV energy.\u003c\/p\u003e\n\u003cimg alt=\"PowMr POW-HVM4.2K-24V-E inverter charger specs graphic: 4200W, MPPT 60–450Vdc, max PV 500V, 120A\" loading=\"lazy\" src=\"https:\/\/tsolar.top\/cdn\/shop\/files\/PowMr-42KW-62KW-Hybrid-Solar-Inverter-24V-48V-to-220Vac.png?v=1779106599\"\u003e\u003cp\u003eA pure sine wave inverter\/charger with MPPT supports wide PV input (60–450Vdc) and up to 120A charging for flexible system design.\u003c\/p\u003e\n\u003cimg alt=\"Wall-mounted PowMr hybrid inverter with battery type options: AGM, GEL, FLD, LI, SLD, and USER; 120A max charge\" loading=\"lazy\" src=\"https:\/\/tsolar.top\/cdn\/shop\/files\/PowMr-42KW-62KW-Hybrid-Solar-Inverter-24V-48V-to-220Vac_779ceec9-0112-442a-876b-60a11b781471.jpg?v=1779106606\"\u003e\u003cp\u003eBattery settings include common lead-acid types plus lithium and a USER mode for custom charging parameters.\u003c\/p\u003e\n\u003cimg alt=\"PowMr inverter menu graphic for 3 charging modes: Solar First, Solar and Utility, and Only Solar\" loading=\"lazy\" src=\"https:\/\/tsolar.top\/cdn\/shop\/files\/PowMr-42KW-62KW-Hybrid-Solar-Inverter-24V-48V-to-220Vac_a3d5f390-4a93-443d-830f-fc2b45b52577.jpg?v=1779106612\"\u003e\u003cp\u003eLCD settings let you switch between three charging modes depending on whether you want PV-only charging or utility support.\u003c\/p\u003e\n\u003cimg alt=\"PowMr hybrid solar inverter protection icons for overload, over\/undervoltage, overtemperature, short circuit, reverse polarity\" loading=\"lazy\" src=\"https:\/\/tsolar.top\/cdn\/shop\/files\/PowMr-42KW-62KW-Hybrid-Solar-Inverter-24V-48V-to-220Vac_2347d907-eb21-494e-8903-8da0fb661246.jpg?v=1779106618\"\u003e\n\u003c\/div\u003e","brand":"PowMr","offers":[{"title":"4.2KW 24V without WF \/ 220-240V \/ United States","offer_id":52239858630930,"sku":"1005010772657616-4.2KW 24V without WF-220-240V-United States","price":287.13,"currency_code":"USD","in_stock":true},{"title":"6.2KW 48V with WF \/ 220-240V \/ United States","offer_id":52239858663698,"sku":"1005010772657616-6.2KW 48V with WF-220-240V-United States","price":359.33,"currency_code":"USD","in_stock":true},{"title":"6.2KW 48V without WF \/ 220-240V \/ United States","offer_id":52239858696466,"sku":"1005010772657616-6.2KW 48V without WF-220-240V-United States","price":339.8,"currency_code":"USD","in_stock":true},{"title":"4.2KW 24V with WF \/ 220-240V \/ United States","offer_id":52239858729234,"sku":"1005010772657616-4.2KW 24V with WF-220-240V-United States","price":306.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0863\/2860\/6994\/files\/S2c693db5ae4c48039f2eeabe5f601f29Q.webp?v=1777887282","url":"https:\/\/tsolar.top\/products\/powmr-4-2kw-6-2kw-hybrid-solar-inverter-24v-48v-to-220vac-mppt-120a-charge-controller-450v-max-pv-voltage-for-home-solar-system","provider":"TSolar","version":"1.0","type":"link"}